Archive | Right Angle Probes RSS feed for this section

2 TESLA EXPOSURE

Magnetic Field Exposure requires non-magnetic materials. By jacketing the fiberoptic cable in non-metallic materials, and by constructing the sensor tip from non-metallic or non-magnetic materials, Philtec sensors can be configured to perform measurements in very high magnetic fields. Successful applications to 12 Tesla have been made.

We recently delivered this sensor; a model D20 high-frequency sensor for 2 Tesla exposure.

Continue Reading ·

Measuring Embedded Objects

Tiny 90° Probes

Philtec specializes in the design of sensor systems for gaining access to hard to reach targets. In March 2019, several dozen model D47 sensors were delivered with long fiber optic cables and very small 90° probes as seen here. The fiber optic cable lengths varied from 21 ft. to 55 Ft. long


D47 2-PART SENSOR SYSTEM


D47 3-PART SENSOR SYSTEM

Continue Reading ·

Custom Probes

Special Probes Made To Customer Requirements

Send us a sketch or drawing of your application requirements. We’ll make a sensor configuration drawing for your review. Email sensors@philtec.com

Continue Reading ·

SENSORS for 400°C

CUSTOMER FEEDBACK

“We just got some feedback about the 9 sensors with special configuration and copper sheathing. They are quite satisfied by the sensors, which are well resisting against the 400°C. They have done several tests and measurement campaigns in laboratory and on flight.”

THE APPLICATION

Philtec has delivered 9 sensors to be used during helicopter flights to measurement displacement of engine components. The sensors have 40 mm displacement range and are designed for 400°C continuous tip exposure.

The sensors are equipped with the following options:
Option B – Connectorized Probe
Option C9 – Bendable Copper Cable Jacket, Part B
Option E2 – 3 m total fiber cable length
Option P – Polynomial Curve Fits
Option Q – Connectorized Power Supply and BNC Outputs
Option T6 – Custom 90° Tip with Threaded Probe Extension
Option T9 – 400°C High Temperature Probe Construction

90° Probes for 400°C
Continue Reading ·

1000°F Application

CUSTOMER FEEDBACK

“I wanted to let you know the sensors worked as designed during our tests.  I may follow up with Chris on a few specific questions as we begin to sift through all of our data.  Thank you again for your professionalism and for all your support.” … Sincerely, VMR, Mechanical Engineer

THE APPLICATION

Five special right angle probes were delivered for a 1000°F tip exposure test.

Continue Reading ·